DTG-60

Balance principle

Parallel guide differential top pan type

Temperature range

Ambient to 1100℃

Measurable range (TG)

±500mg

Measurable range (DTA)

±1000μV

Weight readability

0.1μg

Sample quantity

1g Max. in gross weight

Atmosphere

Air and inert gas

Auto sampler

-

Standard sample

-

Analysis / Print

-

Size

W 367×D 650×H 453mm

Weight

35kg

Power supply Specifications

AC 100 V, 120 V, 230 V, 1300 VA, 50/60 Hz

Read more
Show Less

DTG-60H

Balance principle

Parallel guide differential top pan type

Temperature range

Ambient to 1500℃

Measurable range (TG)

±500mg

Measurable range (DTA)

±1000μV

Weight readability

0.1μg

Sample quantity

1g Max. in gross weight

Atmosphere

Air and inert gas

Auto sampler

-

Standard sample

-

Analysis / Print

-

Size

W 367×D 650×H 453mm

Weight

35kg

Power supply Specifications

AC 100 V, 120 V, 230 V, 1500 VA, 50/60 Hz

Read more
Show Less

DTG-60A

Balance principle

Parallel guide differential top pan type

Temperature range

Ambient to 1100℃

Measurable range (TG)

±500mg

Measurable range (DTA)

±1000μV

Weight readability

0.1μg

Sample quantity

1g Max. in gross weight

Atmosphere

Air and inert gas

Auto sampler

24 samples / tray

Standard sample

Fixed

Analysis / Print

Automatic analysis and automatic report printout

Size

W 367×D 650×H 453mm

Weight

40kg

Power supply Specifications

AC 100 V, 120 V, 230 V, 1300 VA, 50/60 Hz

Read more
Show Less

DTG-60AH

Balance principle

Parallel guide differential top pan type

Temperature range

Ambient to 1500℃

Measurable range (TG)

±500mg

Measurable range (DTA)

±1000μV

Weight readability

0.1μg

Sample quantity

1g Max. in gross weight

Atmosphere

Air and inert gas

Auto sampler

24 samples / tray

Standard sample

Fixed

Analysis / Print

Automatic analysis and automatic report printout

Size

W 367×D 650×H 453mm

Weight

40kg

Power supply Specifications

AC 100 V, 120 V, 230 V, 1500 VA, 50/60 Hz

Read more
Show Less

DTG-60

Temperature range

Room temperature to 1,100 °C (DTG-60/60A)

Measurable range (weight)

±500 mg

Measurable range (differential thermal)

±1,000 µV

DTG-60H

Temperature range

Room temperature to 1,500 °C (DTG-60H/60AH)

Measurable range (weight)

±500 mg

Measurable range (differential thermal)

±1,000 µV

DTG-60A

Temperature range

Room temperature to 1,100 °C (DTG-60/60A)

Measurable range (weight)

±500 mg

Measurable range (differential thermal)

±1,000 µV

Number of settable samples

24 per sample tray (DTG-60A/60AH)

Read more
Show Less

DTG-60AH

Temperature range

Room temperature to 1,500 °C (DTG-60H/60AH)

Measurable range (weight)

±500 mg

Measurable range (differential thermal)

±1,000 µV

Number of settable samples

24 per sample tray (DTG-60A/60AH)

Read more
Show Less