TGA-50 Series - Specs
Thermogravimetric Analyzers
TGA-50
Temperature range: Room temperature to 1000°C/Room temperature to 1500°C (H-type)
Measurement range: ±20, ±200 mg (50-type)
Measurement range: ±20, ±200, ±2000 mg (51-type)
Maximum sample weight: 1 g (including wind bag)/10 g (including wind bag, 51-type)
| Temperature range |
Ambient to |
|---|---|
| Weight measuring range |
20mg, 200mg |
| Readability |
0.001mg |
| Sample mass |
1 g including tare |
| Programmable heating rate |
0.1°C/hour to 99.9°C/min |
| Hold time |
0 to 999min, 0 to 999hour |
| Temperature program format |
99 steps maximum |
| Temperature program file |
up to 100 files |
| Cooling method |
Air-cooled |
| Signal output |
Analog and digital |
| Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
| Dimensions |
W173xD550xH500mm |
| Power supply |
AC100V, 120V, 220V, 240V, 500VA, 50/60Hz |
TGA-50H
| Temperature range |
Ambient to |
|---|---|
| Weight measuring range |
20mg, 200mg |
| Readability |
0.001mg |
| Sample mass |
1 g including tare |
| Programmable heating rate |
0.1°C/hour to 50.0°C/min |
| Hold time |
0 to 999min, 0 to 999hour |
| Temperature program format |
99 steps maximum |
| Temperature program file |
up to 100 files |
| Cooling method |
Air-cooled |
| Signal output |
Analog and digital |
| Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
| Dimensions |
W173xD550xH500mm |
| Power supply |
AC100V, 120V, 220V, 240V, 1.2kVA, 50/60Hz |
TGA-51
| Temperature range |
Ambient to |
|---|---|
| Weight measuring range |
20mg, 200mg, 2g |
| Readability |
0.001mg |
| Sample mass |
10g including tare |
| Programmable heating rate |
0.1°C/hour to 99.9°C/min |
| Hold time |
0 to 999min, 0 to 999hour |
| Temperature program format |
99 steps maximum |
| Temperature program file |
up to 100 files |
| Cooling method |
Air-cooled |
| Signal output |
Analog and digital |
| Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
| Dimensions |
W173xD600xH540mm |
| Power supply |
AC100V, 120V, 220V, 240V, 1kVA, 50/60Hz |
TGA-51H
| Temperature range |
Ambient to |
|---|---|
| Weight measuring range |
20mg, 200mg, 2g |
| Readability |
0.001mg |
| Sample mass |
10g including tare |
| Programmable heating rate |
0.1°C/hour to 50.0°C/min |
| Hold time |
0 to 999min, 0 to 999hour |
| Temperature program format |
99 steps maximum |
| Temperature program file |
up to 100 files |
| Cooling method |
Air-cooled |
| Signal output |
Analog and digital |
| Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
| Dimensions |
W173xD600xH540mm |
| Power supply |
AC100V, 120V, 220V, 240V, 1.5kVA, 50/60Hz |